  • c296ab3b6ac13eda60b1be709a0f9b95.jpg

Smart electricity meter

Model:

CHD-DB

Classification:

Power environment monitoring series


Contact Now
  • Product details
  • Specifications
  • User Guide
  • Packing list
  • After sales warranty
  • Multiple charge measurement

    frequency

    Phase current, mean Phase current (RMS)

    Phase voltage, Mean Phase voltage (RMS)

    Line voltage, Average Line voltage (RMS)

    Active power of each phase, total active power

    Reactive power of each phase, total reactive power

    Each phase apparent power, total apparent power

    Each phase power factor, average power factor

    Electric energy measurement

    Measure power in four quadrants without loss of power.

    Positive active electric energy

    Negative active electric energy

    Positive reactive electric energy

    Negative reactive power

    collect

    Adopt RS485 digital communication interface to collect all data and support MODBUS protocol

    Provide the upper computer demonstration program to facilitate the user to write the upper computer program.

    monitoring

    There are 4 LED indicators to monitor the working status: operation/power pulse/communication transmission/communication reception.

    programmable

    Wiring mode: 3 phase 4 line /3 phase 4 line unbalanced /3 phase 3 line unbalanced /3 phase 3 line unbalanced /1 phase 3 line /1 phase 2 line.

    Communication parameters:

    Local address: 1~247

    Baud: 1200/2400/4800/9600/19200

    Parity bit: odd, even, or none

    Key words:
    • 智能电表
  • Size: 110㎜ (L) * 75㎜ (W) * 72㎜ (H)
    Voltage range: AC220
    Power consumption: 5VA
    Refresh data: 1s
    Measuring range: 30~600V(line voltage) 20~400V(phase voltage)
    Continuous overload: 800V
    Measuring range: 0~60A
    Continuous overload: 100A
    Shock overload: 100A/1s
    Current: 0.5%(10A~60A)
    Voltage: 0.5%(20~400V);
    Line voltage :1.0%
    Power: 2.0%(relative to U*I)
    Power factor: 2.0%
    Frequency: 0.5%(45~60Hz)
    Power: 2.0%(0.5L/0.5C)
    Port: RS-485
    Address: 1-247
    Baud: 1200/2400/4800/9600/19200
    Data bits: 8bits
    Stop bit: 2bits
    Parity bit: odd, even, or none
    Communication protocol: ModBus RTU

    The data listed in this information is for reference only, specific product data to ship with product descriptions shall prevail, subject to change without notice

The data listed in this document is for reference only, and the specific product data is subject to the product description attached to the shipment, which is subject to change without notice

Submit