  • CHD706S4正.jpg
  • CHD706S4俯.jpg
  • CHD706S4俯2.jpg

Intelligent electric door controller

Classification:

Accessory products


Contact Now
  • Product details
  • Specifications
  • User Guide
  • Packing list
  • After sales warranty
  • Easy to connect with CHD806DN16 panel door controller, only 2 standard UTP network cable access, receive controller slot open, half open, fully open, close dry contact signal input, and report the door status, open and close status to the controller;

    Easy to connect with CHD806BOX-E panel door button station, only through one UTP network cable access, RS485 communication for control and status reporting;

    Support the control requirements of seam opening, half opening, full opening and closing of the electric door of the monitoring warehouse;

    Support seam open, half open, fully open, closed door state;

    Support duty room local emergency button: "one-key lock" and "one-key full open" function;

    RS485 adopts hand in hand cascading mode, easy wiring, emergency button also cascaded at the same time, convenient site construction.

    Support Reinforce the electric door in the locked position to prevent misoperation and improve the safety level.

    If the CHD806BOX is on normally, press the On button. The CHD806BOX voice prompt is on. If you press the On button again, the CHD806box voice prompt is off.

    Normally closed, press the "normally closed button", the CHD806BOX voice prompt emergency alarm state; Press the "normally closed button" again. The CHD806BOX voice prompt will release the alarm.

    Voice prompt: External XF03 iFlytek voice device

    Opening/closing mode: (1) Management center CHD806BOX-E32 controls the "open/close" door.

    (2) Software remote control "open/close" door.

  • Overall dimensions: 115 MM (L) X 90MM (W) X 40MM (H) ± 5%

    Net weight: 145g ± 5%

    Color: beige white

    Rated operating voltage: 12VDC

    Input voltage range: 10.8VDC-13.2VDC

    Working current: static standby: ≤50mA; Dynamic unlocking: ≤100mA (when the lock is not charged)

    Minimum supply current: 1000mA / 12V DC input

    Input signal: 12-channel optical coupling isolated dry contact input;

    Output signal: 4 relay dry contact output, 1 relay control plug lock;

    Working environment: -20 ~ 50℃, 20 ~ 90% (no condensation and icing)

    Storage environment: -20 ~ 60℃, 20 ~ 90% (no condensation and icing)

    Resistance index: electrostatic discharge (ESD) : contact discharge ±6kV air discharge ±8kV

    Electrical fast transient pulse group (EFT/B) : The peak voltage of the power supply port is ±2kV

    I/O signal, data port voltage peak ±1kV

    The pulse repetition rate is 5kHz

    SURGE: Power port and communication port cable-wire ±2kV cable-ground ±2kV

    Working state: normal working after power-on, blue light flashing;

    Communication mode: standard RS485; Specification of State Telecommunication Administration: YDN023 -- 1996

    Data communication format: 1,8,1, N

    Communication rate: 19200bps by default

    Address code: The default ID is 1, which can be modified through software Settings. If ID=0, the value is universal

    The data listed in this information is for reference only, specific product data to ship with product descriptions shall prevail, subject to change without notice

The data listed in this document is for reference only, and the specific product data is subject to the product description attached to the shipment, which is subject to change without notice

Submit